Gas Mass Flow meter for Hydrogen and Helium gases

Gas Mass Flow meter for Hydrogen and Helium gases

SKU CMS for Hydrogen and Helium Gases
UOM Each

Azbil CMS Gas Mass Flow Meters for Hydrogen and Helium Gases. Gas must be clean and dry, without corrosive components such as chlorine, sulfur and acid, and without dust or oil mist. Straight pipe length not required if pipe size is uniform. The meter can even be connected to an elbow pipe, allowing for easy design of pipe layout. Corrosive gases cannot be measured. Low tolerance for foreign matter deposits (filter installation required). *The flow meter can also be used for mixed gases containing hydrogen or helium gases by means of the gas type conversion factor function. For details, contact Azbil North America.


Included Products

CMS0010BTSH200100

CMS0010BTSH200100

$1,572.00


CMS0010BTTH200100

CMS0010BTTH200100

$1,512.00


CMS0050BTSH200100

CMS0050BTSH200100

$1,572.00


CMS0050BTSH210100

CMS0050BTSH210100

$1,812.00


CMS0200BTSH200100

CMS0200BTSH200100

$1,814.00


CMS0200BTSH2001Y0

CMS0200BTSH2001Y0

$1,994.00


CMS0200BTTH200100

CMS0200BTTH200100

$1,754.00


CMS0200BTUH200100

CMS0200BTUH200100

$1,694.00


CMS1000BTTH210100

CMS1000BTTH210100

$3,809.00


CMS2000BTSH2001Y0

CMS2000BTSH2001Y0

$5,019.00


Details

Azbil CMS Gas Mass Flow Meters for Hydrogen and Helium Gases are equipped with Azbil Corporations µF (Micro Flow) sensors, which can detect even the slightest gas flow. The flow meters provide mass flow measurement of gas with high speed 2 m response that is unaffected by changes in pressure and temperature. The CMS incorporates a microflow sensor built with silicon micromachining and thin-film technologies. The Symmetric structure measures reverse flow as well. The sensor is located on the pipe wall. High repeatability with ±0.5% FS., high accuracy ± 5% rdg. Pipe size (B) 1/4" and 1/2", flow rate range 0.6 L/min to 2000 L/min. Operating temperature 14 °F (-10 °C) to 140 °F (60 °C). Operating pressure –0.07 to 1 MPa. Sampling time 100 ms ± 20 ms. Analog output signals can be switched among 0 - 5 V, 1 - 5 V and 4 - 20 mA output, selectable using keys on the CMS body. Gas-contracting parts: 316 stainless steel, Flourorubber. RS-485 option available. Inspection results and traceability certificate models available CMS functions include instantaneous flow rate indication, totalized or reverse-totalized flow display, event output, totalizer pulse output, totalized flow reset input, output scaling, gas type switching, etc. for a variety of applications. CMS gas flowmeters are CE approved.